Skip to main content

Table 3 City-specific determinants of hopane concentrations in house settled dust

From: A new exposure metric for traffic-related air pollution? An analysis of determinants of hopanes in settled indoor house dust

City

Final model with regression coefficients

Partial R2

Model Adj.R2

Edmonton

log (hopanes) = 3 – 0.13 cleaning frequency

0.78

0.80

- 1.5 Smooth Flooring

0.78

−0.15 Air Conditioning

0.35

Toronto

Log (hopanes) = 2.69 -1.03 Smooth Flooring

0.29

0.45

−0.008 Elevation

0.13

+ 0.88 Attached Garage −0.66 Detached Garage

0.13%*

Windsor**

log (hopanes) = 5.6 + 0.5 elevation

0.36

0.39

+ 0.17 RD1_100

0.13

Winnipeg

log (hopanes) = 1.45 – 0.057Heating degree days

0.17

0.33

– 1.33 multifamily house

0.16

Vancouver

log (hopanes) = 1.9 – 0.09 Heating Degree Days

0.09

0.10

– 0.07 Shoe removal

0.07

  1. * The Garage variable has three categories: No garage, Attached garage and Detached garage.
  2. ** In Windsor, elevation and distance to the Ambassador Bridge were strongly and significantly correlated. An alternative model with Distance to Ambassador Bridge yielded similar results, yet with smaller R2