Skip to main content

Table 6 Odds ratio (OR) and 95% confidence interval (CI) for meningioma per 100 hours of cumulative use and per year of latency

From: Meningioma patients diagnosed 2007–2009 and the association with use of mobile and cordless phones: a case–control study

 

Per 100 h cumulative use

Per year of latency

 

OR

95% CI

OR

95% CI

Analogue

1.021

1.0004 – 1.042

1.003

0.982 – 1.025

Digital (2G)

1.005

0.99997 – 1.011

0.999

0.979 – 1.020

Digital (UMTS, 3G)

1.035

1.0002 – 1.071

0.929

0.799 – 1.081

Mobile phone, total

1.005

1.001 – 1.010

0.998

0.982 – 1.014

Cordless phone

1.011

1.006 – 1.017

1.008

0.989 – 1.028

Digital type

1.007

1.003 – 1.010

1.003

0.984 – 1.022

Wireless phone

1.006

1.003 – 1.009

1.000

0.984 – 1.016

  1. Adjustment was made for age at diagnosis, gender, SEI-code and year of diagnosis.