Thompson WW, Comanor L, Shay DK: Epidemiology of seasonal influenza: use of surveillance data and statistical models to estimate the burden of disease. J Infect Dis. 2006, 194 (Suppl 2): S82-91. 10.1086/507558.
Article
Google Scholar
Edward D, Elford W, Laidlaw P: Studies of air-borne virus infections. J Hyg (Lond). 1943, 43: 1-15. 10.1017/S0022172400035828.
Article
CAS
Google Scholar
Lester W: The influence of relative humidity on the infectivity of air-borne influenza A virus, PR8 strain. J Exp Med. 1948, 88: 361-368. 10.1084/jem.88.3.361.
Article
CAS
Google Scholar
Loosli CG, Lemon HM, Robertson OH, Appel E: Experimental air-borne influenza infection. I. Influence on humidity on survival of virus in air. Proc Exp Biol Med. 1943, 531: 205-206.
Article
Google Scholar
Hemmes JH, Winkler KC, Kool SM: Virus survival as a seasonal factor in influenza and polimyelitis. Nature. 1960, 188: 430-431. 10.1038/188430a0.
Article
CAS
Google Scholar
Shechmeister IL: Studies on the experimental epidemiology of respiratory infections. III. Certain aspects of the behavior of type A influenza virus as an air-borne cloud. J Infect Dis. 1950, 87: 128-132.
Article
CAS
Google Scholar
Harper G: Airborne Micro-organisms - Survival test with 4 viruses. J Hyg (Lond). 1961, 59: 479-10.1017/S0022172400039176.
Article
CAS
Google Scholar
Hood AM: Infectivity of Influenza Virus Aerosols. J Hyg (Lond). 1963, 61: 331-335. 10.1017/S0022172400039619.
Article
CAS
Google Scholar
Schaffer FL, Soergel ME, Straube DC: Survival of airborne influenza virus: effects of propagating host, relative humidity, and composition of spray fluids. Arch Virol. 1976, 51: 263-273. 10.1007/BF01317930.
Article
CAS
Google Scholar
Edward DG: Resistance of influenza virus to drying and its demonstration on dust. Lancet. 1941, 241: 664-666. 10.1016/S0140-6736(00)72189-1.
Article
Google Scholar
Buckland FE, Tyrrell DA: Loss of infectivity on drying various viruses. Nature. 1962, 195: 1063-1064. 10.1038/1951063a0.
Article
CAS
Google Scholar
McDevitt J, Rudnick S, First M, Spengler J: The Role of Absolute Humidity on the Inactivation of Influenza Viruses on Stainless Steel Surfaces at Elevated Temperature. Appl Environ Microbiol. 2010, 76 (12): 3943-3947. 10.1128/AEM.02674-09.
Article
CAS
Google Scholar
Shaman J, Kohn M: Absolute humidity modulates influenza survival, transmission, and seasonality. Proc Natl Acad Sci USA. 2009, 106: 3243-3248. 10.1073/pnas.0806852106.
Article
CAS
Google Scholar
Shaman J, Pitzer VE, Viboud C, Grenfell BT, Lipsitch M: Absolute humidity and the seasonal onset of influenza in the continental United States. PLoS biology. 2010, 8 (3):
Kalamees T, Korpi M, Vinha J, Kurnitski J: The effects of ventilation systems and building fabric on the stability of indoor temperature and humidity in Finnish detached houses. Building and Environ. 2009, 44: 1643-1650. 10.1016/j.buildenv.2008.10.010.
Article
Google Scholar
TenWolde A: Ventilation, humidity, and condensation in manufactured houses during winter. ASHRAE Transactions. 1994, 100 (1): [http://www.fpl.fs.fed.us/documnts/pdf1994/tenwo94c.pdf]
Google Scholar
Weichenthal S, Dufresne A, Infante-Rivard C, Joseph L: Indoor ultrafine particle exposures and home heating systems: a cross-sectional survey of Canadian homes during the winter months. J Expo Sci Environ Epidemiol. 2007, 17: 288-297. 10.1038/sj.jes.7500534.
Article
CAS
Google Scholar
Lipsitch M, Viboud C: Influenza seasonality: lifting the fog. Proc Natl Acad Sci USA. 2009, 106: 3645-3646. 10.1073/pnas.0900933106.
Article
CAS
Google Scholar
Walton G, Dols WS: CONTAM 2.1 Supplemental user guide and program documentation. 2006, Gaithersburg, MD: National Institute of Standards and Technology
Google Scholar
Emmerich S, Nabinger S: Measurement and Simulation of the IAQ Impact of Particle Air Cleaners in a Single-Zone Building. 2000, Gaithersburg, MD: National Institute of Standards and Technology, [http://www.bfrl.nist.gov/IAQanalysis/docs/NISTIR6461.pdf]
Google Scholar
Emmerich SJ, Nabinger S, Gupte A, Howard-Reed C, Wallace L: Comparison of measured and predicted tracer gas concentrations in a townhouse. 2003, Gaithersburg, MD: National Institute of Standards and Technology, [http://www.bfrl.nist.gov/IAQanalysis/docs/NISTIR_7035_final11-CC.pdf]
Chapter
Google Scholar
Howard-Reed C, Nabinger S, Emmerich SJ: Predicting the performance of non-industrial gaseous air cleaners: measurements and model simulations from a pilot study. 2004, Gaithersburg, MD: National Institute of Standards and Technology
Chapter
Google Scholar
Lansari A, Streicher J, Huber A, Crescenti G, Zweidinger R, Duncan J, Weisel C, Burton R: Dispersion of automotive alternative fuel vapors within a residence and its attached garage. Indoor Air. 1996, 6: 118-126. 10.1111/j.1600-0668.1996.t01-1-00008.x.
Article
CAS
Google Scholar
US DOE: EnergyPlus Version 2.1.0. Washington, DC. 2007, [http://apps1.eere.energy.gov/buildings/energyplus/features.cfm]
Google Scholar
Myatt TA, Minigishi T, Allen JG, MacIntosh DL: Control of asthma triggers in indoor air with air cleaners: a modeling analysis. Environmental Health. 2008, 7: 10.1186/1476-069X-7-43.
Google Scholar
Persily A, Musser A, Leber D: A Collection of Homes to Represent U.S. Housing Stocks. 2006, Gaithersburg, MD: National Institute of Standards and Technology
Chapter
Google Scholar
Howard-Reed C, Polidori A: Database tools for modeling emissions and controls of air pollutants from consumer products, cooking and combustion. 2006, I. Gaithersburg, MD: National Institute of Standards and Technology
Chapter
Google Scholar
Fabian P, McDevitt J, DeHaan WH, Brande M, Milton DK: Influenza virus in fine particles exhaled during tidal breathing and coughing. 2009, American Thoracic Society International Conference. Poster Session. San Diego, CA
Chapter
Google Scholar
Fabian P, McDevitt JJ, DeHaan WH, Fung RO, Cowling BJ, Chan KH, Leung GM, Milton DK: Influenza virus in human exhaled breath: an observational study. PLoS ONE. 2008, 3: e2691-10.1371/journal.pone.0002691.
Article
Google Scholar
Fabian P, McDevitt JJ, Lee WM, Houseman EA, Milton DK: An optimized method to detect influenza virus and human rhinovirus from exhaled breath and the airborne environment. J Environ Monit. 2009, 11: 314-317. 10.1039/b813520g.
Article
CAS
Google Scholar
Milton DK, Fabian P, Angel M, Perez DR, McDevitt J: Influenza Virus Aerosols in Human Exhaled Breath: Particle Size, Culturability, and Effect of Surgical Masks. 2010, American Thoracic Society. Poster Session. New Orleans, LA
Google Scholar
Loudon RG, Brown LC: Cough frequency in patients with respiratory disease. Am Rev Respir Dis. 1967, 96: 1137-1143.
CAS
Google Scholar
Reinikainen LM, Jaakkola JJ, Seppanen O: The effect of air humidification on symptoms and perception of indoor air quality in office workers: a six-period cross-over trial. Arch Environ Health. 1992, 47: 8-15. 10.1080/00039896.1992.9935938.
Article
CAS
Google Scholar
Nordstrom K, Norback D, Akselsson R: Effect of air humidification on the sick building syndrome and perceived indoor air quality in hospitals: a four month longitudinal study. Occup Environ Med. 1994, 51: 683-688. 10.1136/oem.51.10.683.
Article
CAS
Google Scholar
McIntyre DA: Response to atmospheric humidity at comfortable air temperature: a comparison of three experiments. Ann Occup Hyg. 1978, 21: 177-190. 10.1093/annhyg/21.2.177.
Article
Google Scholar
Sale CS: Humidification during the cold weather to assist perennial allergic rhinitis patients. Ann Allergy. 1971, 29: 356-357.
CAS
Google Scholar
IOM: Damp Indoor Spaces and Health. 2004, Washington: National Academy Press
Google Scholar
ASHRAE: Standard 62.1-2007: Ventilation for acceptable indoor air quality. 2007, Atlanta, GA: American Society of Heating, Refrigeration, and Air Conditioning Engineers
Google Scholar
CPSC: Biological Pollutants in Your Home. 1997, Bethesda, MD: U.S. Consumer Product Safety Commission, [http://www.cpsc.gov/cpscpub/pubs/425.html]
Google Scholar
Tellier R: Review of aerosol transmission of influenza A virus. Emerg Infect Dis. 2006, 12: 1657-1662.
Article
Google Scholar
Tellier R: Transmission of influenza A in human beings. The Lancet infectious diseases. 2007, 7: 759-760. 10.1016/S1473-3099(07)70269-4. author reply 761-753
Article
Google Scholar
Brankston G, Gitterman L, Hirji Z, Lemieux C, Gardam M: Transmission of influenza A in human beings. The Lancet infectious diseases. 2007, 7: 257-265. 10.1016/S1473-3099(07)70029-4.
Article
Google Scholar
Nicas M, Jones RM: Relative Contributions of Four Exposure Pathways to Influenza Infection Risk. Risk Anal. 2009, 29: 1292-1303. 10.1111/j.1539-6924.2009.01253.x.
Article
Google Scholar
Glass S, TenWolde A: Review of moisture balance models for residential indoor humidity. Proceedings of the 12th Canadian Conference on Building Science and Technology. 2009, 1: 231-245. [http://www.fpl.fs.fed.us/documnts/pdf2009/fpl_2009_glass001.pdf]
Google Scholar
Emmerich SJ, Persily A, Nabinger S: Modeling moisture in residential buildings with a multizone IAQ program. 2002, Gaithersbur, MD: National Institute of Standards and Technology, [http://fire.nist.gov/bfrlpubs/build03/PDF/b03007.pdf]
Google Scholar
Emmerich SJ, Howard-Reed C, Gupte A: Modeling the IAQ impacts of HHI interventions in inner city housing. 2005, Gaithersburg, MD: National Institute of Standards and Technology, [http://www.fire.nist.gov/bfrlpubs/build05/PDF/b05054.pdf]
Chapter
Google Scholar
Lowen AC, Mubareka S, Steel J, Palese P: Influenza virus transmission is dependent on relative humidity and temperature. PLoS pathogens. 2007, 3: 1470-1476. 10.1371/journal.ppat.0030151.
Article
CAS
Google Scholar